Configuration

EWTS configuration controls message filtering, output destination, and bridge behavior.

Environment variables

Variable Set By Purpose
NGEN_RESULTS_DIR Caller of ngen Directory for ngen log files and the starting point for locating the logging configuration file.
EWTS_USE_NGEN_BRIDGE ngen Signals runtime code to route through the ngen bridge when available.
EWTS_ENABLED ngen EWTS logging enabled or disabled. Based on the logging configuration file.
<module>_LOGLEVEL ngen Individual module log level. Based on the logging configuration file.
RUN_LOGS_DIR RTE Common RTE-provided log directory for run output used by the components.
LD_LIBRARY_PATH Deployment environment Must include EWTS library directories for native bridge loading.
EWTS_PREFIX CMakeLists.txt Root install prefix, commonly /opt/ewts.

Common fields

Field Meaning Typical value
ewts_id Component or module identifier SAC_SMA, SNOW17, TROUTE
level Minimum diagnostic level INFO, WARNING, or numeric level
log_dir Directory for standalone log output RTE run log directory or local ./logs
log_file_name File name for standalone output model.log
running_in_ngen Whether to use ngen bridge routing true inside ngen/RTE
enabled Whether EWTS logging is enabled Build/runtime dependent

Python logger adoption

Use setup_logger() when... Use configure_existing_logger() when...
EWTS should create the component logger. Application code already created the logger.
New component is being integrated. A third-party or existing module logger identity must be preserved.