Getting Started

Choose the integration path

Runtime context Recommended integration
Python module code Install ewts package and use ewts.configure_existing_logger().
C module code Include EWTS runtime C headers and call the C logging functions.
C++ module code Include EWTS runtime C++ headers and call the C++ logging functions.
Fortran module code Use the Fortran logger module wrapper and call the Fortran logging subroutines.
Running under ngen Defaults to USE_EWTS=ON and modules use the ngen bridge methods.
Running standalone Configure the EWTS_LOG_DIR environment variable or allow stdout fallback.
Python component code Install ewts package and use ewts.setup_logger().

Module Python example

LOG = logging.getLogger("LSTM")
try:
    from ewts.helper import getenv_any
    from ewts.logger import configure_existing_logger
    LSTM_USE_EWTS = True
except ImportError:
    LSTM_USE_EWTS = False

...

def __init__(self) -> None:
    if LSTM_USE_EWTS:
        # Determine if running within ngen using EWTS. This must be done  
        # here when the model actually runs vs when it is imported 
        # into the ngen Python interpreter to ensure the env vars are set.
        val = getenv_any("EWTS_USE_NGEN_BRIDGE", "").strip().lower()
        if val in {"1", "true", "yes", "on"}:
            configure_existing_logger(LOG)
        else:
            _configure_stdout_logging()
            LOG.warning("ewts package installed but EWTS_USE_NGEN_BRIDGE not on. Falling back to default logging.")
    else:
        _configure_stdout_logging()

Non-ngen module Python example

from ewts import setup_logger

LOG = setup_logger(
    ewts_id="MY_COMPONENT",
    level="INFO",
    log_dir="./logs",
    log_file_name="my_component.log",
    running_in_ngen=False,
)

LOG.info("Starting component")
LOG.status('<MSG_DATA>{"status":"STARTING","prog":0.0,"msg":"Starting model","modnm":"MY_COMPONENT"}</MSG_DATA>')

Runtime decision checklist

Question Why it matters
Is the code running inside ngen? Determines whether messages should go through the bridge.
What is the EWTS ID? Controls message attribution and module split behavior.
Should logs go to a file? If not, standalone mode falls back to stdout.
Are payload messages required? RTE progress visibility depends on payload messages.
Is a pre-existing Python logger already created? Use configure_existing_logger() instead of replacing it.